설명
This product has many advantages such as a scientific and efficient temperature control system and photoelectric system, powerful and easy-to-use software analysis functions, and humanized control methods. It can easily achieve downstream multiple gene detection, quantitative analysis, SNP analysis, melting curve analysis and other applications. At present, it is widely used in medical institutions at all levels, universities and research institutes, CDC, immigration inspection and quarantine bureau, public security criminal investigation material identification center, veterinary stations, food companies and dairy products industries.
주요 기능
1. Rapid temperature rise and fall, the maximum rise and fall rate can reach 6.1 ℃ / s;
2. Highlight maintenance-free LED light source for fast fluorescence scanning;
3. 10.4 inch full color touch screen, the device can run independently from the computer, store more than 1000 experimental data;
4. With auto-recovery experiment function when power off and call again,No need to wait for the PC and software to open.
사양
| Detection flux | 96 |
| Applicable supplies | 0.2ml 96-well plate, 8 tubes, single tube (transparent, frosted, milky white are applicable) |
| Number of fluorescence channels | 6 |
| Applicable fluorescein | Channel 1: FAM, SYBR Green I, SYTO 9, EvaGreen, LC Green
Channel 2: HEX, VIC, TET, JOE Channel 3: ROX, Texas Red Channel 4: Cy5 Channel 5: Alexa Fluor 680 Channel 6: FRET |
| Applicable probe | Taqman probe, molecular beacon probe, scorpion probe, FRET probe, etc. |
| Reaction system | 0 ~ 100μl |
| Linear range | 1 ~ 1010 copies |
| Sample detection repeatability | Ct value CV≤0.5% |
| Sample linear | /r/≥0.999 |
| Control method | Stand-alone operation: Use the instrument’s 10.4-inch touch screen and software system to create a new experiment and run it.
Network operation: (1) Direct PC connection: After the instrument is connected to the PC via a point-to-point network, the application software on the computer is used to implement experiments, monitoring, data analysis and other operations; (2) LAN access: By setting the network parameters of the instrument, the instrument can be connected to the local LAN, so that any computer in the local area network can perform operations such as instrument monitoring, data synchronization, and analysis. |
| Automatic sample bin | Sample compartment can be automatically popped / closed by touch screen control;
When the pop-up state is closed, you can touch the sample compartment to close automatically. |
| Power failure protection | With the function of automatically resuming the experiment when the power is cut off and then power on, there is no need to wait for the PC and software to open |
| Data transmission | Experimental data can be imported and exported via USB flash drive |
| Storage | Can store more than 1000 experiment data files |
| Optical system | |
| Light source | Bright long-life maintenance-free LED light source |
| Detector | Photodiode (PD) |
| Detection location | Top excitation, top scan |
| Detection method | Six fluorescence channels are scanned from hole to hole simultaneously without fluorescence edge effect |
| Detection time | Complete detection of 96 wells in 6 fluorescence channels in 7 seconds |
| Excitation light wavelength | Channel 1: 465nm Channel 2: 527nm Channel 3: 580nm Channel 4: 632nm Channel 5: 680nm Channel 6: 465nm |
| Detection light wavelength | Channel 1: 510nm Channel 2: 563nm Channel 3: 616nm Channel 4: 664nm Channel 5: 730nm Channel 6: 616nm |
| Fluorescence linear | r≥0.990 |
| Dynamic range for fluorescence detection | Dynamic range of fluorescence detection can be adjusted according to reagents |
| Temperature Control System | |
| Cover temperature | Room temperature ~ 110 ℃ |
| Constant pressure hot cap | Compatible with consumables of different heights |
| Module temperature | 0℃~100℃ |
| Module temperature control principle | Peltier effect, semiconductor refrigeration technology |
| Maximum temperature rise / fall rate | Maximum heating rate ≥6.1 ℃ / s Maximum cooling rate ≥5.0 ℃ / s |
| Temperature uniformity | ±0.1℃ |
| Temperature accuracy | ≤±0.1℃ |
| Gradient temperature width | 1℃~40℃ |
| Gradient temperature number | 12 columns |
| Special temperature setting function | Supports thermal gradient PCR experiments, Long PCR, Touch Down PCR |
| Software functions | |
| Analysis function | Qualitative analysis, absolute quantitative analysis, relative quantitative analysis, endpoint fluorescence analysis, melting curve analysis, SNP analysis, etc. |
| Report customization | Pre-stored multiple industry experiment report models;
Board full open universal report function, users can customize report content and form; |
| Rights management function | The administrator account can limit the functions of “manually set thresholds”, “running settings”, “running experiments”, and “analysis data” of ordinary accounts to manage the use rights of instruments of ordinary accounts |
| Resource sharing function | After the instrument is connected to the PC, both parties can realize the synchronous sharing of experimental data through operations such as uploading and downloading. |
왜 저희를 선택해야 할까요?
- 경쟁력 있는 가격으로 공장 직판합니다.
- CE 및 ISO 인증을 획득한 최고급 품질입니다.
- 뛰어난 제품 OEM 및 ODM 맞춤 제작 역량.
- 확실한 생산 및 정시 납품을 약속드립니다.
- 완벽한 사후 서비스와 무료 제품 부속품 제공.
저희 공장
당사는 표준화된 생산 공장과 완벽한 생산 팀을 갖추고 있습니다. 이들은 모든 제품을 생산할 때 항상 진지하고 책임감 있는 태도를 유지합니다. 당사의 연구개발(R&D) 팀은 설계 엔지니어, 기술 전문가, 자격을 갖춘 전문가, 공정 관리 담당자 등 다방면의 전문 엔지니어들로 구성되어 있습니다. 당사의 자격을 갖춘 전문가들은 제품 설계, 연구 개발, 시험, 생산, 품질 검사 및 포장을 포함하는 당사의 품질 공정 관리 시스템을 바탕으로 공정에 대한 포괄적인 감독을 엄격히 수행하고 있습니다.
포장 및 배송
당사의 제품 포장은 오랜 기간 동안 그 신뢰성이 입증되었으며, 일반적으로 합판 상자나 트레이가 포함된 골판지 상자를 사용합니다. 상품의 무게와 크기에 따라 적절한 포장을 준비해 드리겠습니다. 물론, 고객님께서 포장 형태를 직접 선택하실 수도 있습니다.
고객 사례
당사의 실험실 기기 및 장비는 수많은 과학 실험실, 과학 연구 기관, 대학, 병원, 질병통제센터 및 기타 기관에서 사용되고 있으며, 다수의 유명 바이오제약, 신에너지, 전자 기업, 식품 가공, 환경 보호 분야 기업들과 협력 관계를 맺고 있습니다. 기업 간 협력을 통해 당사의 안정적이고 신뢰할 수 있는 제품은 전 세계 120여 개국으로 수출되고 있으며, 이들로부터 높은 평가를 받고 있습니다. OQTSUPPLIES를 믿어 주십시오. 우리는 함께 성장해 나가겠습니다!