Automatic Kjeldahl Nitrogen Analyzer

Auto Kjeldahl Nitrogen Analyzer is perfessional instrument which used to analysis protein content and nitrogenious compounds in nature.It widely used fast protein analysis in filed of Food,Milk,Meat,Drink,Medicine,Soil and feed.

규정 준수: CE 인증 획득
맞춤형: OEM/ODM
포장: 합판 케이스 포장

제품

설명

LKN9830 Kjeldahl semi-auto analyzer is an auto analyzer which with characters including auto reagent addition, auto distillation and separation of sample, auto collection of samples and auto termination of distillation; the separation methods which adopted by the LKN9830 is 100% corresponds to the National and International standards.

주요 기능

1.  Manual/auto double-mode switch and automatically adding quantitative alkali liquor and boric acid absorbent solution

2. 10 experimental procedures can be stored to meet users’ different requirements. Distillation time can be set at will. After distillation completion, it will give an alarm automatically.

3.  Automatic cleaning system realizes intelligent pipeline cleaning function which make measuring accuracy higher.

4.  Perfect safety protection system can measure and protect over-temperature and over pressure of distiller and pipeline.

5.  Intelligent design of facilities around Kjedahl Apparatus contains safety protection design and non-existence prompt function.

6.  Intelligent cooling water control system can control and inspect cooling water

7. Emergency stop operating function for emergency

8.  Automatic inspection of failures and intelligent audible and visual alarm system

사양

모델 LKN9830
Measuring   range 0.1—200 mg N
Recovery ratio ≥99.5%
 Repeatability precision(RSD) ≤0.5%
Weight of measured samples solid≦6g;  liquid≦20ml
Amounts of water filling, alkali filling, acid filling 0—100ml
Sample separation time 3-5min
Distillation time 0-600mins
Automatic distillation mode 10 kinds of   distillation programs
Operation mode auto/manual   dual mode
Display mode 6inch LCD
Alarm and shutdown temperature 120℃
Maximum power 1300W
전력 220V 50HZ
Overall dimension 420mm*450mm*700mm
무게 32kg

OPTIONAL

1. sample crusher

2. digestion furnace

3. exhaust gas collection device

4. neutralization device

5. refrigeration cycler

6. digestive tube support

7. digestive tube

8. catalytic sheet

9. reflux funnel

FAQS

1. What are the main applications of nitrogen analyzers in those industries?

A: The nitrogen analyzer is mainly used to determine the content of nitrogen and crude protein in the sample. Mainly used in food, feed, agriculture, research institutes, medicine, universities, daily chemical, soil fertilizer, etc. Kjeldahl method for the determination of nitrogen and crude protein in samples.

2. What is the difference between automatic nitrogen analyzer and traditional manual method?

Answer: The automatic nitrogen analyzer does not require human intervention throughout the experimental procedure after setting the corresponding laboratory conditions. It has many advantages such as fast test speed, high efficiency, good parallel test results, and low risk factor.

3. How to ensure the recovery rate of the sample?

A: The main factors affecting the recovery rate are distillation time, alkali addition, excessive boric acid, complete digestion, and instrument sealing. Cooling water flow, water pressure, and water temperature are too high.

4. What are the classifications and differences of common nitrogen analyzers in the market?

A: There are many current classifications in the market. The most common classifications are:

1. Semi-automatic nitrogen analyzer: Only the distillation part does not contain titration. Titration requires manual titration. There are two types of semi-automatic currently available on the market:

1) manually add alkali, manually add water, manually control the distillation time.

2) Automatic addition of alkali, automatic hydration, automatic acid addition, no human intervention is required throughout the distillation experiment.

2. Fully automatic Kjeldahl nitrogen analyzer: integrated design of distillation and titration. After the sample is completely digested, the instrument is automatically added with water, automatically added with alkali, automatically hydrated, and automatically added with acid.

Automatic titration and result calculation printing. No human intervention is required throughout the experimental process, which greatly reduces the workload of laboratory personnel, improves work efficiency, and tests

The result is more accurate.

5. What are the faults and solutions that often occur during the use of the nitrogen analyzer?

A: 1. Alkaline pump and pipeline are blocked. The instrument should be cleaned and maintained frequently after use.

2. The steam generator has a short service life. Distilled or pure water must be used in the steam generator to avoid scale formation.

6. Can the nitrogen analyzer use other color indicators?

A: If you use manual titration, you can choose other color indicators. If a fully automatic instrument is used, the color indicator should be configured according to the ratio specified in the product, and other reagents should not be replaced. The built-in color change process of the product has been adjusted to the best condition at the factory to ensure the accuracy of the results.

7. Can the nitrogen analyzer be equipped with digestive tubes of different specifications and different manufacturers?

A: No, each manufacturer’s digestive tract has standard sizes and specifications. The size is not the same as the matching of the machine. It is recommended to configure the digestive tube produced by the original factory.

8. Can the nitrogen analyzer be used for other distillation experiments in addition to determining the nitrogen content in the sample?

A: In theory, it is ok. The specific depends on different experiments, depending on the different needs of the experiment.

9. What does the sample recovery rate mean?

A: The sample recovery rate represents the accuracy of the instrument and also reflects the manufacturing process of the entire instrument. Therefore, the sample recovery rate is an important indicator for evaluating the quality of the equipment.

10. What are the special requirements of the nitrogen analyzer for the laboratory environment?

A: 1. It is necessary to ensure normal laboratory power supply.

2. must ensure that the water supply and drainage of the laboratory is smooth.

3. The instrument is placed at a distance of no more than 1.5m from the tap water source.

4. All digestive experiments must be carried out in a ventilated place in accordance with national regulations.

11. What is the cause of the cooling water flow and insufficient water pressure at the interface of the nitrogen analyzer?

A: The main reason for the shortage of cooling water flow and water pressure is that the laboratory tap water pressure is insufficient or the water tower is used, and the floor is too high. The booster pump can be added according to the specific conditions of the laboratory or the water pressure can be adjusted by itself.

12. How long is the life of the nitrogen analyzer?

A: The design life of the nitrogen analyzer is 10 years, depending on the amount of your own experiment and the daily maintenance.

13. When the boric acid absorption solution absorbs, there will be bubbles, which will affect the result.

A: No, because there will be bubbles in the process of condensation, which will follow the ammonia water into the absorption liquid. It is a normal phenomenon and has no effect on the experimental results.

14. What are the consumables and consumables of the nitrogen analyzer?

A: The wearing parts of the nitrogen analyzer are mainly digestive tubes. Because they are glass products, collisions and hanging rubs are inevitable during daily use. It is recommended to configure a part of the digestive tract. The consumables of the product are mainly reflected in the daily experimental reagents, mainly copper sulfate (catalyst) potassium sulfate (increasing the boiling point of sulfuric acid) concentrated sulfuric acid, boric acid, sodium hydroxide, hydrochloric acid and the like.

15. Does the Kjeldahl test still need other instruments?

A: Need, mainly the balance, drying oven, mortar, and related experimental glassware.

16. Can the nitrogen analyzer be used with different brands of digestion instruments?

A: It is necessary to determine whether the digestion aperture of the digestion instrument is consistent with the supporting manufacturer. In order to ensure the accuracy of the whole experimental results and the efficiency of the experiment, it is recommended to purchase the original compatible digestion instrument.

17. What is the definition of semi-automatic and fully automatic nitrogen analyzer?

A: Kjeldahl has three main steps: digestion, distillation, and titration.

The semi-automatic nitrogen analyzer has only a distillation part, and the fully automatic nitrogen analyzer refers to an all-in-one machine containing distillation and titration.

18. How to ensure the service life of Kjeldahl?

A: The service life of the nitrogen analyzer depends on the raw materials, processing technology and after-sales service adopted by different manufacturers. Because the Kjeldahl test involves many factors such as strong acid, alkali, high temperature, etc., the daily maintenance and maintenance of the instrument is also an important factor in determining the service life of the instrument.

19. What are the safety protection functions of the nitrogen analyzer?

A: 1. The digestive tract is not in place: When the digestive tract is not placed or placed improperly, it will alarm, effectively preventing the lye from being directly added to the instrument, thus ensuring the service life of the instrument.

2. Safety door protection: The main function of the safety door is to protect the safety of the experimental personnel and the instrument. When the safety door is not closed or the closing is not complete, the instrument will alarm and remind the experiment.

Room personnel were closed in time.

3. cooling water flow water pressure real-time detection: cooling water is the key factor for accurate and normal operation of the instrument. When the cooling water is insufficient, the water temperature is too high, the laboratory stops water, etc.

When the factors affecting the results of the experiment appear, the machine will automatically stop working and alarm.

4. Over-temperature alarm: When the temperature of the steam generator is too high, the instrument automatically stops working and alarms to ensure the safety of the instrument.

20. Does the nitrogen analyzer require the identification of the quality inspection department?

A: The nitrogen analyzer is not in the product catalogue of the national mandatory verification. It is not a measuring instrument, so it does not require the verification by the quality inspection department.

21. How to verify the accuracy of the nitrogen analyzer test results?

A: It can be calibrated with a standard sample of known sample content. Generally, the ammonia sulfate is commonly used for calibration and calibration of the instrument.

왜 저희를 선택해야 할까요?

  1. 경쟁력 있는 가격으로 공장 직판합니다.
  2. CE 및 ISO 인증을 획득한 최고급 품질입니다.
  3. 뛰어난 제품 OEM 및 ODM 맞춤 제작 역량.
  4. 확실한 생산 및 정시 납품을 약속드립니다.
  5. 완벽한 사후 서비스와 무료 제품 부속품 제공.

 

저희 공장

당사는 표준화된 생산 공장과 완벽한 생산 팀을 갖추고 있습니다. 이들은 모든 제품을 생산할 때 항상 진지하고 책임감 있는 태도를 유지합니다. 당사의 연구개발(R&D) 팀은 설계 엔지니어, 기술 전문가, 자격을 갖춘 전문가, 공정 관리 담당자 등 다방면의 전문 엔지니어들로 구성되어 있습니다. 당사의 자격을 갖춘 전문가들은 제품 설계, 연구 개발, 시험, 생산, 품질 검사 및 포장을 포함하는 당사의 품질 공정 관리 시스템을 바탕으로 공정에 대한 포괄적인 감독을 엄격히 수행하고 있습니다.

포장 및 배송

당사의 제품 포장은 오랜 기간 동안 그 신뢰성이 입증되었으며, 일반적으로 합판 상자나 트레이가 포함된 골판지 상자를 사용합니다. 상품의 무게와 크기에 따라 적절한 포장을 준비해 드리겠습니다. 물론, 고객님께서 포장 형태를 직접 선택하실 수도 있습니다.

 

고객 사례

당사의 실험실 기기 및 장비는 수많은 과학 실험실, 과학 연구 기관, 대학, 병원, 질병통제센터 및 기타 기관에서 사용되고 있으며, 다수의 유명 바이오제약, 신에너지, 전자 기업, 식품 가공, 환경 보호 분야 기업들과 협력 관계를 맺고 있습니다. 기업 간 협력을 통해 당사의 안정적이고 신뢰할 수 있는 제품은 전 세계 120여 개국으로 수출되고 있으며, 이들로부터 높은 평가를 받고 있습니다. OQTSUPPLIES를 믿어 주십시오. 우리는 함께 성장해 나가겠습니다!

제품 관련

1
1
1
1
맨 위로 이동

문의하기

2005년에 설립된 OQT의 팀은 2010년부터 실험실 장비 분야에 진출하여, 실험실 장비 및 기기의 해외 사업을 담당하고 있습니다.

문의하기