설명
The refrigeration part is mechanically refrigerated by a fully enclosed compressor, composed of plate heat exchangers, expansion valves, and pressure protectors to meet the cooling requirements; the heating part is the use of electric heating tubes to heat the circulating fluid. And through the built-in circulating pump, the external circulating pipeline transports the refrigerant or the heat medium to the interlayer of the supporting equipment, and indirectly cools and heats the materials in the reactor.
During external circulation, connect the upper outlet pipeline of the product to the lower inlet pipeline of the kettle body, and the circulating fluid will return from the upper circulation port through the pipeline to the lower return port of the product to form a complete circulation space.
The heating and cooling of the explosion-proof high and low temperature circulator can be quickly switched. The medium used (high and low temperature silicone oil) is the same medium, and there is no need to change the medium after connection.
The entire liquid cycle of the high and low temperature cycle device is airtight, with an expansion vessel. The expansion vessel and the liquid cycle are insulated, and do not participate in the liquid cycle, but are only mechanically connected. No matter whether the temperature of the liquid cycle is high or low, the expansion vessel The medium in the medium is below 60°C. It can be achieved that there is no absorption of water vapor at low temperatures, and no oil mist is produced at high temperatures.
주요 기능
1. The temperature control accuracy is generally ±1°C, and an external sensor can be connected (the temperature difference accuracy of installing an external sensor is generally ±0.5°C).
2. It has a PLC computer module, which can be connected to a computer, can realize remote control, can realize multi-point continuous temperature control, segmented temperature control, constant temperature, and one computer can control multiple high and low temperature devices. (It is more convenient to use, and work efficiency is improved to a greater extent)
3. Equipped with USB interface, with data download function. (Data download function enables customers to download and store data related to materials that have been tested or reacted, and provide reference data for testing)
4. Maximum temperature limit to prevent the equipment from getting out of control (if the maximum temperature is exceeded, the equipment will automatically power off to prevent damage to the equipment due to excessive temperature)
5. Power supply protection (①the power supply is missing item ②the live wire is wrong item ③the voltage is too high or too low (display error code E-01)
6. Compressor overheating protection (the compressor will stop working when the compressor’s withstand limit is reached, and the error code E-O2 will be displayed).
7. The water cooling has water flow and low water pressure protection (error code E-03 is displayed).
8. Sensor protection (display error code E-04).
9. All compressors are imported compressors (France, Denmark).
Note:
(1) The high and low temperature circulation device is connected to the oil pipe of the reactor, which should not exceed 4 meters (the return and return oil pipes are 2 meters each), and the connecting oil pipe exceeds 4 meters to break the glass of the reactor body.
(2) The temperature rise and fall rate of the high and low temperature cycle device is affected by the surrounding environment. (Generally, the maximum temperature range of the environment is 30℃)
(3) In areas with relatively humid environments in the south (humidity>50%), explosion-proof type should be adopted.
(4) Both the high and low temperature circulation device and the oil circuit connection of the reactor adopt “low inlet and high outlet”.
사양
| 모델 | OLGD-300/40EX | OLGD-300/80EX |
| Matched reactor | 300L | 300L |
| Tank Volume(L) | 80 | 80 |
| Heating volume(L) | 50 | 50 |
| Heating tank size(mm) | ¢550*550 | ¢550*550 |
| Oil tank size(mm) | 800*800*800 | 800*800*800 |
| Working temperature range(℃) | -40℃ to +200℃ | -80℃ to 200℃ |
| Ambient temperature(℃) | ≤25 | ≤25 |
| Lowest temperature (No load) | -40℃ | -82℃ |
| 전력 | 380V±10% 50HZ | 380V±10% 50HZ |
| Heating power(W) | 18000 | 24000 |
| Temperature accuracy(℃) | ±0.1 | ±0.1 |
| Sensor | PT100 | PT100 |
| Medium quality degree | 500C.S.T | 500C.S.T |
| Circulating pump power(w) | 750 | 750 |
| Lift head(m) | 22 | 22 |
| Flow(L/min) | 80 | 80 |
| The compressor adopts explosion-proof treatment (explosion-proof control box, explosion-proof circulating pump, explosion-proof fan, explosion-proof tube) explosion-proof grade ExdIIBT4 | ||
왜 저희를 선택해야 할까요?
- 경쟁력 있는 가격으로 공장 직판합니다.
- CE 및 ISO 인증을 획득한 최고급 품질입니다.
- 뛰어난 제품 OEM 및 ODM 맞춤 제작 역량.
- 확실한 생산 및 정시 납품을 약속드립니다.
- 완벽한 사후 서비스와 무료 제품 부속품 제공.
저희 공장
당사는 표준화된 생산 공장과 완벽한 생산 팀을 갖추고 있습니다. 이들은 모든 제품을 생산할 때 항상 진지하고 책임감 있는 태도를 유지합니다. 당사의 연구개발(R&D) 팀은 설계 엔지니어, 기술 전문가, 자격을 갖춘 전문가, 공정 관리 담당자 등 다방면의 전문 엔지니어들로 구성되어 있습니다. 당사의 자격을 갖춘 전문가들은 제품 설계, 연구 개발, 시험, 생산, 품질 검사 및 포장을 포함하는 당사의 품질 공정 관리 시스템을 바탕으로 공정에 대한 포괄적인 감독을 엄격히 수행하고 있습니다.
포장 및 배송
당사의 제품 포장은 오랜 기간 동안 그 신뢰성이 입증되었으며, 일반적으로 합판 상자나 트레이가 포함된 골판지 상자를 사용합니다. 상품의 무게와 크기에 따라 적절한 포장을 준비해 드리겠습니다. 물론, 고객님께서 포장 형태를 직접 선택하실 수도 있습니다.
고객 사례
당사의 실험실 기기 및 장비는 수많은 과학 실험실, 과학 연구 기관, 대학, 병원, 질병통제센터 및 기타 기관에서 사용되고 있으며, 다수의 유명 바이오제약, 신에너지, 전자 기업, 식품 가공, 환경 보호 분야 기업들과 협력 관계를 맺고 있습니다. 기업 간 협력을 통해 당사의 안정적이고 신뢰할 수 있는 제품은 전 세계 120여 개국으로 수출되고 있으며, 이들로부터 높은 평가를 받고 있습니다. OQTSUPPLIES를 믿어 주십시오. 우리는 함께 성장해 나가겠습니다!